STC Rating Explained: How to Measure Soundproofing Effectiveness

Sound Transmission Class (STC) is the standard single-number rating for how well a wall, floor, door, or window blocks airborne sound. Here's how STC is measured, what common ratings mean, where the system falls short, and how to improve any assembly.

STC Rating Explained: How to Measure Soundproofing Effectiveness

Controlling sound is essential to creating functional, comfortable spaces — whether ensuring speech privacy in an office, protecting a studio, or preventing sound from traveling between apartments. The primary metric used in the United States is the Sound Transmission Class (STC) rating: a single number describing how well a partition reduces airborne sound transmission. A higher STC means better sound insulation.

How is an STC rating measured?

STC is determined in a controlled laboratory per ASTM E90. A sample partition is built between an isolated source room and receiving room; a source generates noise across 16 one-third-octave bands from 125 Hz to 4000 Hz; microphones measure the Transmission Loss (TL) at each frequency; and the resulting curve is fitted to a reference contour per ASTM E413. The STC rating is the value on the fitted contour at 500 Hz.

What do different STC ratings mean?

STCAudibility of speechExample
25–30Normal speech easily understoodBasic interior wall
35–40Loud speech audible, not intelligibleStandard office/residential wall
45–50Loud speech not audible — privacy beginsIBC apartment walls, conference rooms
55–60+Very loud sounds faintly heardLuxury condos, studios, sensitive labs

The International Building Code requires a minimum STC of 50 for assemblies separating dwelling units. For sensitive spaces like executive offices, STC 55+ is often specified.

Limitations of the STC system

The most significant limitation is frequency range: STC only measures down to 125 Hz, so it does not account for low-frequency noise such as home-theater bass, heavy machinery rumble, or traffic and aircraft. For those situations, the Outdoor-Indoor Transmission Class (OITC) — which extends down to 80 Hz — is more appropriate. STC is also a laboratory rating; real installations are subject to flanking paths (ductwork, ceiling plenums, gaps around outlets) that reduce real-world performance.

How to improve an assembly's STC rating

  • Add mass. Thicker or extra layers of drywall, or mass-loaded vinyl, make partitions harder for sound to vibrate.
  • Improve absorption. Filling a stud cavity with fiberglass or mineral wool dissipates sound energy.
  • Decouple the structure. Double-stud walls, staggered studs, resilient channels, or isolation clips break the vibration path.
  • Seal all gaps. Acoustic sealant at joints and penetrations prevents small leaks from ruining an otherwise strong assembly.

For a truly effective design, look beyond the single number — understand the limits of STC, consider OITC where low-frequency noise matters, and treat the entire assembly, from materials to construction quality to sealing.